Termite and Borer Treatment Standards in India: What to Ask For Before Carpentry Starts
"Anti-termite treated" and "borer-proof" appear on almost every plywood quotation, and almost none of them name a standard. India has standards for both problems, but they are not the same standards, and most of them sit outside the BIS certification that is now mandatory for plywood. This guide sets out what each covers and what you can actually ask for in writing.
The short answer
Termites and borer are two different problems with two different sets of standards. Subterranean termites come from the soil and travel through the building into anything made of wood; the standard for stopping them is IS 6313, anti-termite measures in buildings. Borers are beetles whose larvae eat the wood itself; protection against them is a property of the board, covered by IS 401 for timber and IS 12120 for plywood and other panels.
The practical consequence: no board, however well treated, fixes a termite colony that is already in the wall. That is treated at the building first. Board treatment is what protects the furniture after.

Which standard covers what
| Standard | Current edition | Covers |
|---|---|---|
| IS 6313 (Part 1) | 1981 | Constructional measures against subterranean termites |
| IS 6313 (Part 2) | 2022 | Pre-constructional chemical treatment of the soil |
| IS 6313 (Part 3) | 2022 | Treatment of existing buildings, including the woodwork in them |
| IS 401 | 2001 (reviewed 2021) | Preservation of timber, including furniture and cupboards |
| IS 12120 | 1987 (reaffirmed 2010) | Preservation of plywood and other panel products, including glue-line treatment against borer |
| IS 5539 | 1969 | Preservative-treated plywood; not under the plywood Quality Control Order |
For an interior project in a flat that is already built, the two that matter most are IS 6313 Part 3, for the building, and IS 12120, for the boards.
Termites already in the building: IS 6313 Part 3
IS 6313 (Part 3):2022 covers treatment of existing buildings. We have read the 2001 edition it replaced, which sets out the approach a homeowner will recognise:
- Infested woodwork, door frames and shelves are treated by injecting chemical into small drilled holes.
- Timber damaged beyond repair is replaced, and the new timber is dipped or brushed with preservative at least twice.
- Electrical switch boxes, a common termite route, are treated separately.
- Periodical inspection is necessary: the standard expects follow-up checks in later hot, humid seasons, not a single visit.
If you see mud tubes on a wall, hollow-sounding skirting or damage in an old wardrobe, this treatment comes before demolition and carpentry, not after. A new carcass fixed to an infested wall is the easiest food in the flat.
For a new building, IS 6313 Part 2 governs the soil treatment done during construction. Its 2001 edition says that once the treated soil barrier is formed it shall not be disturbed, and that if it is, the barrier must be restored straight away. That matters on a ground-floor flat or a villa when flooring or plumbing work digs into the base.
The chemicals, and what is still legal
The 2022 edition of Part 2 lists chlorpyrifos, imidacloprid and bifenthrin for soil treatment. Lindane, which the 2001 edition listed beside chlorpyrifos, has been dropped.
Chlorpyrifos is still registered in India. A 2020 draft order proposed banning 27 pesticides including it, but the final Insecticides (Prohibition) Order, 2023 (S.O. 4294(E)) banned only dicofol, dinocap and methomyl, and removed only chlorpyrifos's ber, citrus and tobacco uses. Imidacloprid and bifenthrin are not named in it. A contractor using any of the three is not using a banned chemical.
Borer: what the plywood standards say
IS 12120 is the standard for treating plywood and panels against borer. For interior dry use, such as cupboards, it allows glue-line poisoning: a preservative mixed into the adhesive that bonds the veneers, for example boric acid or a boric acid and borax mix in the resin. That is what most "borer-proof" claims on interior plywood mean.
IS 303:2024, the general-purpose plywood standard, now asks the manufacturer to declare it. The 2024 edition applies a test for resistance to fungal decay to all three grades, allows "any other type of preservative treatment", and under the BIS product manual a licence holder must declare its type of preservative treatment. Ask the supplier what that declared treatment is.
Marine plywood goes further. The 2010 edition of IS 710 made pressure treatment with preservative mandatory, at a minimum retention of 12 kg/m³ of a copper-based preservative. We have not seen whether the 2024 edition changed that figure.
"Treated to IS 5539" is a claim, not a certification. IS 5539 covers preservative-treated plywood, but it is not one of the standards in the plywood Quality Control Order, so there is no mandatory BIS licence behind it to look up. Our board standards guide covers the marking and licence check for the standards that are under the order.
Solid timber: IS 401
Where solid wood is used, for door frames, beading or a hardwood counter, IS 401:2001 applies. It classes species by natural durability from graveyard tests at FRI Dehradun: Class I lasting 120 months or more, Class II 60 to 120 months, Class III under 60 months. As we read it, it expects the sapwood of every species, even a durable one, to be treated, along with the heartwood of non-durable species. Ask which species the timber is, and whether the sapwood has been treated.
What to ask before carpentry starts
From the pest-control contractor:
- Which part of IS 6313 the treatment follows: Part 3 for a building already standing.
- The chemical and its concentration, written on the invoice.
- When the follow-up inspection will be, since the standard expects more than one visit.
From the board supplier or your interior firm:
- The standard and grade of each board, for example IS 303:2024 BWR or IS 710:2024.
- The preservative or glue-line treatment the board carries, by name.
- For solid timber, the species and whether the sapwood is treated.
The honest limits
No standard we read gives a service life for an anti-termite treatment, and none requires a contractor to issue a treatment certificate or a warranty, so treat any "10-year protection" figure as the contractor's own promise and get it in writing. We read the 2001 editions of IS 6313 Parts 2 and 3 in full; for the 2022 editions we have confirmed the editions and the chemicals listed, not every clause or dose. Whether IS 5539 is still in force could not be confirmed.
Written by Gogineni Kalyaan Kumar
Kalyaan is Principal at AlcorOne Solutions, the interior contracting firm he co-founded in 2022. He has overseen 80+ turnkey residential, villa, and commercial fit-outs across Chennai, Hyderabad, Bengaluru and Vizag, with a focus on itemised BOQs, heavy-duty modular execution, and durable interior systems built for South India’s climate.
Sources & references.
Standards, regulatory registries, and manufacturer references that back the material grades, pricing framework, and compliance points in this guide:
Frequently asked questions.
Which Indian Standard covers anti-termite treatment?
IS 6313, anti-termite measures in buildings. Part 1 (1981) covers constructional measures, Part 2 (2022) covers pre-constructional chemical treatment of the soil, and Part 3 (2022) covers treatment of existing buildings, including infested woodwork.
Is chlorpyrifos banned in India for termite control?
No. A 2020 draft order proposed banning it, but the final Insecticides (Prohibition) Order, 2023 (S.O. 4294(E)) banned only dicofol, dinocap and methomyl and removed only chlorpyrifos's ber, citrus and tobacco uses. IS 6313 Part 2:2022 lists chlorpyrifos, imidacloprid and bifenthrin for soil treatment.
What makes plywood borer-proof?
Usually glue-line treatment: a preservative such as boric acid mixed into the adhesive between the veneers, which IS 12120 allows for interior dry use. Under IS 303:2024 the licence holder must declare its type of preservative treatment, so ask the supplier what it is.
Is "treated to IS 5539" plywood BIS certified?
Not on that basis. IS 5539 covers preservative-treated plywood but is not in the plywood Quality Control Order, so there is no mandatory BIS licence behind the claim. Check the board's IS 303 or IS 710 marking and licence instead.
How long does anti-termite treatment last?
No Indian Standard gives a figure. IS 6313 expects follow-up inspection in later hot, humid seasons, and a treated soil barrier that is disturbed must be restored straight away. Any number of years is the contractor's own promise, so get it in writing.
How are AlcorOne projects paid for?
Projects require an upfront deposit of 20% of the total contract value before work begins, adjusted against the final invoice. The remaining payment is released in milestones tied to project progress — material procurement, civil and carpentry completion, finishing and handover — and the exact milestone schedule is agreed in writing for each project, since it varies with project size, scope and site conditions. Anything not listed in the signed BOQ is out of scope until it is agreed in writing as a variation, costed and confirmed before execution. Published rates are exclusive of GST.
What warranty does AlcorOne give on its interior work?
Three tiers, stated separately because they cover different things and expire at different times. Ten years on the plywood carcass from the date of handover, against delamination, borer attack and manufacturing defect in the board — conditional on the grade specified in the signed BOQ being the grade supplied and installed. One year on installation and workmanship: alignment, levelling, fixing, edge-banding and similar. Hardware, fittings and appliances carry the manufacturer's own term, and AlcorOne registers that documentation in the client's name at handover and facilitates the claim. Not covered under any tier: water ingress originating from base-building or plumbing defects outside AlcorOne's scope; damage from misuse, unauthorised modification, or third-party work carried out after handover; and normal wear to finishes.
Termites are fixed at the building and borer is fixed in the board. A quotation that only says "anti-termite treated" does neither in writing.
Ask for the standard, the grade and the treatment on every board line, and for the IS 6313 part and the chemical on the pest-control invoice. Those are short facts, and each one is something you can check.
Want the board's treatment named in the quotation?
A board line that names the standard, the grade and the preservative is one you can check against what arrives on site.
Get a callback + itemised BOQ
Leave your name and number — we'll call you back with a scope and a ballpark BOQ for your Hyderabad project. No obligation.